Wednesday, 29 March 2017

How will you design a perfect Lean Battery Room

The use of forklift battery keeps upward, pushing as business grow to be greater awareness of their company social responsibilities, aiming to have as little negative environmental effect as feasible from their operations.

Whether operating a single unit or a fleet of forklifts you'll want to have a chosen lean battery charging station to charge batteries whilst essential.

This article will examine lean battery charging room design, taking off some key layout concerns in order to make certain a secure battery charging room.



·         Acid resistant floors
Because of the corrosive nature of battery acid, the flooring of a lean battery charging room ought to be resistant to acid harm, so that you can additionally lead to an easier smooth-up in the case of a spill. Not having an acid resistant floor structural damage may additionally occur in the case of a spill.

·         Proper air flow
While recharging and for a quick period after the charge is completed forklift batteries provide off hydrogen fuel, which is why right air flow is imperative to make certain the safety of workers within the immediate region of lean battery charging station.
Further, the ventilation may be furnished through right manner, inclusive of openings at the pinnacle of buildings or can be automatically assisted via the setup of exhaust fans.



·         Ventilation Stands and exhaust duct community
The lean battery room has designed to capture hydrogen fuel with or without pressured air flow. In a case, a gas exits the batteries, it goes through a network of ducts to soundly go out the constructing with the assist of the Hydrogen Exhaust Fan (HEF). Further, when the lean Battery Room Ventilation System is used in conjunction with the Electrical Distribution System, the non-compulsory Charger Shutdown disables the charger whilst a high quantity of hydrogen (approximately higher than 2%) is found within the area. After discontinuing the chargers, the supply of hydrogen gas is interrupted.

·         Correct charging point set up
When designing a battery charging room, it's miles crucial that charging factors are mounted efficaciously. Chargers should be wall installed and geared up with emergency prevent breakers to prevent the float of energy in an emergency. Further, when charging more than one unit right now there must additionally be a minimum of 1 metre gap the complete manner spherical, each machine for easy get right of entry to while necessary.

It is suggested to install a good design of a lean battery station in your warehouses which helps to increase the lifespan of the forklift batteries. 






No comments:

Post a Comment